Telecommunication Cables

500 FLEXIBLE BRAIDED COAXIAL CABLE

Application: It is used as connection wire inside equipment and jumper cable for base station and antennas, and any other place in which need coaxial cable with high performance.

Conductor : Bare Copper / Copper Clad Aluminum
Insulation : Foamed Polyethylene
Shielding : Tinned Copper Wire
    Braiding over Bonded Aluminium Foil
Sheath : PVC / PE / LSZH

Product Constructions
Construction RF Link
100
RF Link
195
RF Link
200
RF Link
240
RF Link
300
RF Link
400
RF Link
500
RF Link
600
Inner Conductor 0.46 0.94 1.12 1.42 1.78 2.74 3.61 4.47
Dielectric 1.52 2.80 2.95 3.81 4.83 7.24 9.40 11.56
Outer Conductor 2.11 3.53 3.66 4.52 5.72 8.13 10.29 12.45
Jacket 2.79 4.95 4.95 6.10 7.62 10.29 12.70 14.99
Product Properties
  RF Link
100
RF Link
195
RF Link
200
RF Link
240
RF Link
300
RF Link
400
RF Link
500
RF Link
600
Min. bending
radius (mm)
6.4 12.7 12.7 19.1 22.2 25.4 31.8 38.1
Flat plate
crush resistance kg/mm
0.18 0.27 0.27 0.36 0.54 0.71 0.89 1.07
Max. pulling
force (Kg)
6.8 18.2 18.2 36.3 54.5 72.6 118 158.9
(O/km) DC Inner Conductor
resistance Outer Conductor
104
31.2
24.94
16.08
17.59
16.08
10.50
12.76
6.96
7.25
3.07
5.41
2.69
4.17
1.74
3.94
Insulation
resistance MO - Km
5000
Dielectric Strength
(KV)
1.6
Velocity of
Propagation %
66 80 83 85 86 87 86 87
Peak Power
rating (KW)
0.6 2.5 2.5 5.6 10 16 22 40
Cut off
frequency (GHz)
90 41 39 31 24.5 16.2 12.6 10.3
Characteristic
impedence
50
VSWR
(Operational frequency)
= 1.2
(VDC)
voltage withstand
500 1000 1000 1500 2000 2500 3000 4000
(pF/m)
capacitance
101.1 79.5 80.4 79.4 79.1 78.4 77.4 76.8
µH/m
inductance
0.25 0.21 0.20 0.20 0.20 0.20 0.19 0.19
Shielding
effectiveness
>90 dB
Phase Stability <10 ppm / °C

Attenuation (@ 20° C) & average power (@ ambient temperature 40° C, inner conductor temperature 100° C)

  Frequency
(MHz)
RF Link
100
RF Link
195
RF Link
200
RF Link
240
RF Link
300
RF Link
400
RF Link
500
RF Link
600
Attenuation
(dB/100 mtr)
30 12.9 6.5 5.8 4.4 3.5 2.2 1.8 1.4
50 16.7 8.4 7.5 5.7 4.5 2.9 2.3 1.8
150 29.4 14.6 13.1 9.9 7.9 5.0 4.0 3.2
220 35.8 17.7 15.9 12.0 9.6 6.1 4.9 3.9
450 51.9 25.5 22.8 17.3 13.8 8.9 7.1 5.6
900 74.9 36.5 32.6 24.8 19.9 12.8 10.3 8.2
1500 98.7 47.7 42.4 32.4 26.0 16.8 13.6 10.9
1800 109.0 52.5 46.6 35.6 28.7 18.6 15.0 12.1
2000 115.5 55.4 49.3 37.7 30.3 19.6 15.9 12.8
2500 130.6 62.4 55.4 42.4 34.2 22.2 18.0 14.5
3000 143.8 68.9 61.3 47.1 38.2 25.0 20.4 16.7
Average
Power
(KW)
30 0.23 0.78 0.91 1.30 1.78 2.72 2.91 4.93
50 0.18 0.60 0.70 1.00 1.38 2.13 2.21 3.83
150 0.10 0.35 0.40 0.58 0.79 1.22 1.28 2.16
220 0.08 0.29 0.33 0.48 0.65 1.00 1.05 1.77
450 0.06 0.20 0.23 0.33 0.45 0.69 0.72 1.23
900 0.04 0.14 0.16 0.23 0.31 0.48 0.50 0.84
1500 0.03 0.11 0.12 0.18 0.24 0.36 0.38 0.63
1800 0.03 0.10 0.11 0.16 0.22 0.33 0.34 0.57
2000 0.03 0.09 0.11 0.15 0.21 0.31 0.33 0.54
2500 0.02 0.08 0.10 0.13 0.18 0.27 0.29 0.48
3000 0.02 0.08 0.09 0.12 0.17 0.25 0.26 0.44


Cat 5e cable

Parameter Data SFTP FTP UTP
Conductor 24 AWG Annealed Bare Solid copper O O O
Insulation 1 mm Nom. High Density Polythene O O O
Pairs Blue/white - Blue, Orange / White - Orange O O O
  Green / White - Green, Brown / White - Brown O O O
Laying 4 Pair laid together O O O
Binding Polyester Tape O O X
Shield Aluminium Bonded Polyester Tape O O X
Braiding and Coverage 0.1 mm Nom. more than 60% O X X
Drain Wire 26 AWG Tinned Copper O O X
Sheathing (External Jacket) FR PVC for Indoor / PE for Outdoor O O O
Jacket Dia In mm Nominal 6.5 6 5.5
Vertical Flame Spread of single cable As per IEC 60332-1 O O O
Vertical Flame Spread of Bunched Cables As per IEC 60332- 3 -24 Category C O O O
Amount of Halogen acid gas As per IEC 60754-1 20 Mg/g max O O O
Corrosivity of Combustion Gases As per IEC 60754-2 O O O
Smoke Density As per IEC 61034-2 less than 60% SDR O O O
Conductor Resistance at 20°C 94 O / km Max. O O O
Insulation Resistance at 20°C = 5 MO / Km. O O O
High Voltage Test 1500 V for 1 Min. Withstood O O O
Capacitance 53 +/- 5nf /km O O O
Impedance 100 ± 15 O O O O
Attenuation Frequency in MHz Attenuation In dB per 100 meter cable
1 2.2 2.2 2
10 6.7 6.7 6.5
20 9.3 9.3 9.3
100 22 22 22
Next Frequency in MHz NEXT In dB
1 65.3 65.3 65.3
10 50.3 50.3 50.3
20 45.8 45.8 45.8
100 35.3 35.3 35.3
Cable Printing   SPEEDLINK

24 AWG 4
Pair Category
5e SFTP Cable
SPEEDLINK

24 AWG 4
Pair Category
5e FTP Cable
SPEEDLINK

24 AWG 4
Pair Category
5e UTP Cable
Packing 500/305/100 meter O O O

NOTE: "O" indicates available and "X" indicates not available.


Cat 6 Cable

Parameter Data SFTP FTP UTP
Conductor 23 AWG Annealed Bare Solid copper O O O
Insulation 1 mm Nom. High Density Polythene O O O
Pairs Blue/white - Blue, Orange / White - Orange O O O
  Green / White - Green, Brown / White - Brown O O O
Laying 4 Pair laid together O O O
Binding Polyester Tape O O X
Shield Aluminium Bonded Polyester Tape O O X
Braiding and Coverage 0.1 mm Nom. more than 60% O X X
Drain Wire 26 AWG Tinned Copper O O X
Sheathing (External Jacket) FR PVC for Indoor / PE for Outdoor O O O
Jacket Dia In mm Nominal 7 6.5 6
Vertical Flame Spread of single cable As per IEC 60332-1 O O O
Vertical Flame Spread of Bunched Cables As per IEC 60332- 3 -24 Category C O O O
Amount of Halogen acid gas As per IEC 60754-1 20 Mg/g max O O O
Corrosivity of Combustion Gases As per IEC 60754-2 O O O
Smoke Density As per IEC 61034-2 less than 60% SDR O O O
Conductor Resistance at 20°C 76 O / km Max. O O O
Insulation Resistance at 20°C = 5 MO / Km. O O O
High Voltage Test 1500 V for 1 Min. Withstood O O O
Capacitance 53 +/- 5nf /km O O O
Impedance 100 ± 15 O O O O
Attenuation Frequency in MHz Attenuation In dB per 100 meter cable
1 2 2 1.9
10 6.7 6 6
20 9.3 8.5 8.5
100 22 19 19
150 24.7 24.7 24.7
200 29 29 29
250 32 32 32
300 35.6 35.6 35.6
Next Frequency in MHz NEXT In dB
1 74.3 74.3 74.3
10 59.3 59.3 59.3
20 54.8 54.8 54.8
100 44.3 44.3 44.3
150 41.7 41.7 41.7
200 39 39 39
250 37 37 37
300 35.3 35.3 35.3
Cable Printing   SPEEDLINK

23 AWG 4
Pair Category
6 SFTP Cable
SPEEDLINK

23 AWG 4
Pair Category
6 FTP Cable
SPEEDLINK

23 AWG 4
Pair Category
6 UTP Cable
Packing 500/305/100 meter O O O

NOTE: "O" indicates available and "X" indicates not available.


CAT-5 S-FTP LAN Cable Assembly

Part No. Product Description
STCA-53xx 1 CAT-5 SFTP LAN Cable Straight Assembly
STCA-53xx 2 CAT-5 sftp LAN cable Cross Assembly
Note : xx stands for Length in Mtr.
Product Details
Cable CAT 5 S-FTP
Connector RJ-45 Shielded
Cable Length Customer Req.
Technical Specifications
Mechanical  
Inner Conductor 24 AWG bare solid copper
Over all Shield Tinned copper braiding, 0.1mm dia
Insulation Dia 1.05 mm nominal
Insulation Material Polyethylene
Drain Wire 26 AWG ATC
Sheath Material PVC
Sheath Dia 6 mm Nominal
Electrical Specifications
Impedance 100 ± 150
Conductor Resistance @ 20°C 94.8 ohm/km. max.
Capacitance 50±5 nf/km
Insulation Resistance constant at 27°C 5 G-ohm-km (min.)
AC HVT test in water 1.5 KV for one Minute
Heat Shock Test on insulation
at 150°C for 1 Hour
No cracks
Flammability test As per IEC 60332
Return Loss =21 dB @ 100Mhz
Frequency 1 MHz 10 MHz 20 MHz 100 MHz
Attenuation at 20°C / 100 Mtr. 2.2 dB 6.7 dB 9.4 dB 22 dB
NEXT (min) at 20°C 65.5 dB 50.3 dB 45.9 dB 35.8 dB